Near W 154th St, Overland Park 2 years ago
RHEEM
Model
41V50
Rating
Feedback No
Posted
Age
18 Years
Size
50 GALLON
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
Expansion Tank
NO
Valve Meter
NO
PRV
YES
Water Softner
NO
Installation Type
Installation
Water Pressure Inside
45 psi
Water Pressure City
N/A
Old Description
Replace a hot water tank due to a major remodel that included removing the flue from the house.
New Description
Install AO Smith power vent with 2\" PVC. The vent was a 15\' run with a total of 3 90\'s. A thermal expansion tank was installed a set to 85 psi. The water pressure was increased inside the house from 45 to 75 psi. An isolation valve was also installed to service and maintain the thermal expansion tank.
Feedback by Customer
Chase was a great help from the first call, came out the next day to help move a remodeling schedule forward, and did an amazing and great looking job with the installation. One of the more satisfying experiences I've ever had with a home service professional. Highly recommended.
Overall Experience
Product Knowledge
Punctuality
Quality of Work

See Profile...