Near W 48th St, Shawnee 9 months ago
AO SMITH
  • AO Smith with unsecure flue
Model
GCV50400
Rating
Feedback
Posted
Age
9 Years
Size
50 GALLON
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Expansion Tank
NO
Valve Meter
YES
PRV
NO
Water Softner
YES
Installation Type
Installation
Water Pressure Inside
80 psi
Water Pressure City
80 psi
Old Description
The old water heater was in the perfect storm for tank failure. The water softener had the biggest impact on the tank failure as much rust was present. The draft diverter was also not secured resulting in improper venting of flue gases. The flue was redone and the new tank installed.
New Description
New flue installed and thermal expansion tank put in. The water softener was bypassed and a PRV was installed.