Near N Amoret Ave, Kansas City 2 months ago
STATE SELECT
Model
Rating
Feedback
Posted
Age
12 Years
Size
50 GALLON
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
GAS VALVE / PILOT
Expansion Tank
NO
Valve Meter
NO
PRV
YES
Water Softner
NO
Installation Type
Installation
Water Pressure Inside
75 psi
Water Pressure City
100 psi
Old Description
The old water heater had an improper venting configuration. The water pressure was also much higher than it was suppose to be. The vent for the water heater went from 6" to 3" which is against code.
New Description
The gas line was updated with a new shutoff and drip leg and also hard piped. The vent was replaced to 4" and the old wye from the furnace was removed. There was also a 1' rise off the top of the tank that was added. A new PRV and thermal expansion tank was also installed.